Changzhou Haiers Medical Devices Co., Ltd. >> Reloading Disposable Cartridge for Endoscpic Linear Cutter Stapler

Reloading Disposable Cartridge for Endoscpic Linear Cutter Stapler

Reloading Disposable Cartridge for Endoscpic Linear Cutter Stapler
Price: US $ 75-85/Piece
Trade Terms: FOB,FCA,EXW
Min Order: 1/Piece
Pay Type: L/C,T/T,D/P,Western Union,Paypal
Prod Model: HASQJ/Z -30/45/60/30H/45H/60H
Markets: South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Product Name: Cartridge for Endoscpic Linear Cutter Stapler
Certificates: CE0197, ISO
Model: Hasqj/Z -30/45/60/30h/45h/60h
MOQ: 1PC
Leading Time: 3-5days for Trial Order, 10-15days for Bulk Order
Application: Abdominal
Feature: Disposable
Certification: ISO13485
Group: Adult
Type: Cartridge for Endoscpic Linear Cutter Stapler
Material: Titaninum

Product Description

Reloading Disposable Cartridge for endoscpic Linear Cutter Stapler
I. Indications
 
The product is used for resection, transection and anastomosis of tissue during abdomen, maternity, pediatric and thoracic surgery.

II. External structure
1. Nail Box          2.Nail Retainer       3. Cutter Knife       4.Connecting Rod

III. Specification Model
Reloading Cartridge in individual package is available, including three specs: 30mm, 45mm and 60mm.
Basic dimensions of reloading unit
TYPESuture length(mm)Cartridge length(mm)Staple height (Inner)Staple height (Middle)Staple Height (Outer)
HASQJ/Z -30301203.53.54.0
HASQJ/Z -45451803.53.54.0
HASQJ/Z -60602403.53.54.0
HASQJ/Z -30H301204.04.55.0
HASQJ/Z -45H451804.04.55.0
HASQJ/Z -60H602404.04.55.0

IV. Instructions For Use
1.According to the different use scopes at surgery, choose the part of stiching instrument and relevant suture units.
2.Install units. Install suture units on the part of stiching instrument, aim the socket of suture units at the top socket of part.(The indication sign of units must be aligned with the indication sign of part.)Then, insert in the end. Contrarotate the suture units 45 degress. The suture units will be locked immediately.

Attention: 1) Install units when it is switched on, cannot turn off.
                2) Don't remove insurance board before the units is not installed,otherwise the reloading head can not normally open after cut.
                3) Make sure the reset handle of part is fully send back. After install units,clasp the free handle once to close the jaw, then push back the reset handle to make the jaw open up.
3.Unload units. Unload suture units from the part of stiching instrument. Pull back the locking cards. Rotate units 45 degrees clockwise and pull forward the part.
Attention: 1) Rotary knob must in the middle.
                2) Make sure the reset han
dle of part is fully return.
4.Using instrument. Depending on the different nailing suture units, choose the different trocar as a converter: the nail height is 3.5,3.5,4.5 ,select trocar of12mm or larger trocar.The nail height is 4.0,4.5,5.0 ,select trocar of15mm.
1)Before the instrument insert the trocar.First take down the insurance panel from the units.Second clasp the free handle to close the jaw.Third,instrument insert into a suitable size or larger trocar.
2)Pull the reset handle is fully return.Open the instrument jaws.Put into the body cavity immediately.
Attention: I. Nail retainer must be completely exposed when you open the suture units jaws of the body cavity.(Over the trocar)

               II. Do not clasp the free handle when return the reset handle.
               III. To make sure no obstacle sandwich.
3)Turn the adjusting housing.Suture.Enable the suture units 3600 axial rotation.Turn the knob around.Enable rotary suture units 45 degrees swing.
4) Clasp the free handle to close the jaw,thereby cutting off the tissue,the instrument will not cut the tissue before the green lockpin is not pressed.
Attention: I.The product has self-locking mechanism with empty units.Empty cartridge can not be percussed twice.
               II. Allow to open the jaw before
the reset handle is fully return.The jaw can reposition.
5) Push the insurance button to percuss the instrument.Gradually clasping the free handle.The locking plate arrive at the end of units clip groove,clasp the free handle,complete percussing.
6) After percussing the instrument entirely,First pull the reset handle return to open the jaw,the instrument is then slowly withdrawn from the body cavity.After instrument completely exit,unload suture units.
Attention: I. Do not put the instrument insert or remove the casing while the instrument in the hole
                II. At the same stage surgery,instrument can replace units and percuss 25 times.


V. Attention
1. The product is disposable. It can be used after open the sterilized packing. It is forbidden to use if the package is damaged.
2.The product is disposable and is sterilized by EO. The packing is sterile and sealed. There is "sterile" on the packing box and also on it. The date of sterilization and the caveat which said it is forbidden to use if the package is damaged are also on the packing box. Sterilization period of validity is three years.
3.This instruction is only for general introducing and it can not be the instruction of the operation. The operator should take correlative medical literature
4. Dispose the instrument after use.

VI. 
Storage
The product shall be stored in a well-ventilated room where no corrosive gases exist and relative humidity is not more than 80%.
  
VII. Package
The inner packing is sterilized and sealed plastic bliaster. The medium packing is colorful box and each colorful box contains one piece of instrument. The outer packing is carton.

Changzhou Haiers is a modern, efficient and well managed organization focused and committed on the care and safety of the patients upon whom their products are used. Our credo of "When you put patients' health first, remarkable things happen" are not just empty words!

The professional institution engaged in developing, manufacturing and promoting iatric instrument and devices, Welcome to Changzhou Haiers Medical Devices Co., Ltd is located in Changzhou ZhongLou Hi-Tech Development Zone in the Yangtze Delta where it is a historical culturally and economically well-developed area in China. It has employed a powerful group of researchers and working staff and covers a land of 10, 000sqm on which built a 106 grade spotless workshop, a bio-culture lab, a watering system and other production facilities. The management of the institute has been audited with the conformity of ISO9000 and its products have gained the approvals in China and CE for the European markets. The institute has been dubbed as "The Jiangsu Hi-Tech Enterprise" and its have been authenticated as "Jiangsu Hi-Tech Product".

Haiers Stapler is an innovator in stapler technology. We offer a broad range of industry-leading and technologically advanced devices for surgery, as well as a full range of professional medical education and customer support services. We invite you to explore our Web site. In addition to information about our company and products, surgeons and medical staff can find out about events, training and educational opportunities with Haiers Stapler.

Send your message to this manufacturer

  • Changzhou Haiers Medical Devices Co., Ltd.

More >

Other Products with This Manufacturers